Model Comparison
|
|
30XA 080-120 |
30XA 140-350 |
30XA 400-500 |
| |
|
|
|
| Refrigeration Circuit |
| Full R-134a Refrigerant Charge |
Std |
Std |
Std |
| Full Load Factory Run Test and Run Test Report |
Std |
Std |
Std |
| Independent Refrigeration Circuits |
Std |
Std |
Std |
| Rotary Screw Compressors |
Std |
Std |
Std |
| Compressor Protection |
Std |
Std |
Std |
| ~3600 Step Electronic Expansion Valve (EXV) |
Std |
Std |
Std |
| Flooded Shell-and-Tube Cooler |
Std |
Std |
Std |
| Cooler Insulation |
Std |
Std |
Std |
| Filter Drier |
Std |
Std |
Std |
| Moisture Indicating Sight Glass |
Std |
Std |
Std |
| AeroAcoustic Condenser Fans |
Std |
Std |
Std |
| Low-Sound Compressor Enclosures |
Std |
Std |
Std |
| High Ambient Condenser Fan Motors |
N/A |
FIOP |
FIOP |
| EnviroShield Condenser Coil Coatings |
|
| Pre-Coated Al/Cu Fins |
FIOP |
FIOP |
FIOP |
| Cu/Cu Condenser Coils |
FIOP |
FIOP |
FIOP |
| E-Coated Al/Cu Condenser Coils |
FIOP |
FIOP |
FIOP |
| E-Coated Cu/Cu Condenser Coils |
FIOP |
FIOP |
FIOP |
| Compressor Suction Service Valve |
FIOP |
FIOP |
FIOP |
| Suction Line Insulation |
FIOP |
FIOP |
FIOP |
| Liquid & Discharge Circuit Service Valves |
Std |
Std |
Std |
| Chilled Water Circuit |
| 300 psig (2068 kPa) Fluid Side Rated (150 psig for 400 to 500 ton units) |
Std |
Std |
Std |
| Electronic Flow Switch (thermal dispersion) |
Std |
Std |
Std |
| Medium Temperature Brine |
FIOP |
FIOP |
FIOP |
| Freeze Protection ( Cooler Heaters) |
Std |
Std |
Std |
| Controls / Communication |
| Microprocessor ComfortLink™ Control |
Std |
Std |
Std |
| Navigator™ Display |
Std |
Std |
Std |
| Remote Enhanced Display |
Accy |
Accy |
Accy |
| Hinged Access Panels |
Std |
Std |
Std |
| Temperature & Pressure Display |
Std |
Std |
Std |
| Energy Management Module (EMM) |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| Chilled Water Temperature Reset (from return fluid) |
Std |
Std |
Std |
| Chilled Water Temperature Reset (via 4-20 mA signal; EMM required) |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| Demand Limit (via 4-20mA signal, 2-step; EMM required) |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| Load Shedding (Carrier Comfort Network required) |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| Low Water Temp Protection |
Std |
Std |
Std |
| High Pressure Protection |
Std |
Std |
Std |
| Low Pressure Protection |
Std |
Std |
Std |
| Compressor Lead/Lag Control (cycles & run-time) |
Std |
Std |
Std |
| Unit Mounted Control Panel |
Std |
Std |
Std |
| Low Ambient Head Pressure Control |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| Anti-Cycling Protection |
Std |
Std |
Std |
| Minimum Load Control |
Accy |
Accy |
Accy |
| Carrier Comfort Network Communication Capability |
Std |
Std |
Std |
| DataPort™ Control |
Accy |
Accy |
Accy |
| DataLink™ Control |
Accy |
Accy |
Accy |
| BACnet Translator Control |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| LON Translator Control |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| Electrical |
| Single Point Primary Power Entry |
Std |
Std |
Std |
| Dual Point Primary Power Entry |
N/A |
N/A |
Std |
| Control Transformer |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| Unit Mounted Main Disconnect, Non-fused |
FIOP |
FIOP |
FIOP |
| On-Off Switch |
Std |
Std |
Std |
| 115V GFI Convenience Outlet |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| Across-the-line Compressor Start (except for 200 & 230V units above 100 tons) |
Std |
Std |
Std |
| Wye-Delta Compressor start (Std on 200 & 230V units above 100 tons) |
FIOP |
FIOP |
FIOP |
| Packaging / Security |
| Condenser Coil Trim Panels |
Std |
Std |
Std |
| Security Grilles |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
| Condenser Coil Hail Guards |
FIOP/ Accy |
FIOP/ Accy |
FIOP/ Accy |
- Std - Standard
- FIOP - Factory installed option
- Accy - Accessory
- N/A - Not available
|